Site Initializer - Synchronization for Layout Segment Experiences is broken

thumbnail
Vitaliy Koshelenko, modified 1 Year ago.

Site Initializer - Synchronization for Layout Segment Experiences is broken

Expert Posts: 319 Join Date: 3/25/11 Recent Posts

Steps to reproduce:

1. Enable Update Supprot for SI: https://liferay.dev/blogs/-/blogs/site-initializers-update-support

2. Define Layouts for Segment Experiences in SI module.

3. Deploy SI module, and create a site from SI.

4. Run Syncronize.

Expected behavior: everything stays the same if no changes were made to SI

Actual behavior: segment experiences are duplicated.

ReasonBundleSiteInitializer._addSegmentsExperiences method is not deisgned for update support. 

thumbnail
David H Nebinger, modified 1 Year ago.

RE: Site Initializer - Synchronization for Layout Segment Experiences is broken

Liferay Legend Posts: 14933 Join Date: 9/2/06 Recent Posts