Ask - Test
Site Initializer - Synchronization for Layout Segment Experiences is broken
Vitaliy Koshelenko, modified 1 Year ago.
Site Initializer - Synchronization for Layout Segment Experiences is broken
Expert Posts: 319 Join Date: 3/25/11 Recent PostsSteps to reproduce:
1. Enable Update Supprot for SI: https://liferay.dev/blogs/-/blogs/site-initializers-update-support
2. Define Layouts for Segment Experiences in SI module.
3. Deploy SI module, and create a site from SI.
4. Run Syncronize.
Expected behavior: everything stays the same if no changes were made to SI
Actual behavior: segment experiences are duplicated.
Reason: BundleSiteInitializer._addSegmentsExperiences method is not deisgned for update support.
David H Nebinger, modified 1 Year ago.
RE: Site Initializer - Synchronization for Layout Segment Experiences is broken
Liferay Legend Posts: 14933 Join Date: 9/2/06 Recent Posts